Skip to main content

Spontaneous complete migration of suture material after subcuticular continuous suture in cesarean section: a case report

Abstract

Background

Skin closure during cesarean section is often performed with subcuticular running sutures by using a nonabsorbable suture material. However, this material has the risk of incomplete removal after wound healing and can migrate to other sites in rare cases.

Case presentation

A 34-year-old Korean woman who had undergone a cesarean section 5 months prior presented with a fine, blue object visible through the skin on her left lower abdomen. No pain or any other signs of inflammation were observed. The foreign body was revealed to be 10-cm-long suture material that had migrated laterally approximately 15 cm in intradermal layer during the previous 5 months, without tangling of the entire length.

Conclusions

Small remnants of suture materials in the subcutaneous tissue are known to migrate toward the superficial layer. The mechanism of these migrations is often thought to be related to foreign body immune reaction or the force generated in wound contracture. Long-distance migration of relatively long suture materials, as in the present case, has not been reported yet. Such a steady tension in a uniform direction within a human tissue layer cannot be explained clearly by the previously described mechanisms. That migration might have occurred in superficial subcutaneous tissue layers through the horizontal flow or movement of those layers during the recovery process that have not been revealed yet.

Peer Review reports

Background

A transverse suprapubic (Pfannenstiel) incision is widely used during cesarean section, and the skin closure is often performed with a subcuticular running suture, which might be associated with a low risk of wound complications compared to staples [1]. Either absorbable or nonabsorbable sutures can be used. Nonabsorbable sutures do not leave buried knots that can be associated with complications such as granulomas or abscesses [2]. However, the material of these sutures has a risk of incomplete removal after wound healing and can migrate to other sites in rare cases.

Case presentation

A 34-year-old, para 1, Korean woman underwent emergent cesarean section at 34 weeks of gestation in the Korea University Medical Center Anam Hospital in March 2012 because of preterm premature rupture of the membrane and breech presentation. Her body mass index (BMI) was 22.1 kg/m2. She was diagnosed with a uterus didelphys and vaginal septum but had no other medical or surgical history. A transverse suprapubic (Pfannenstiel) incision was performed during the cesarean section. A 2.42-kg male baby was delivered, without perioperative complications. After closure of the subcutaneous layer, the skin was closed with subcuticular running sutures by using a 3-0 nonabsorbable monofilament nylon suture (AILEE Inc., Busan, South Korea). The distal part of that string was snapped during the wound dressing on postoperative day 4, and the resident ordered the discharge of the patient on the next day without removal of the remaining string. Five months after the patient was discharged, she presented to the outpatient clinic with a fine, blue object visible on the left lower quadrant of her abdomen. A 10-cm thread-like foreign body showed through her skin. It was situated transversely; the medial end was located approximately 5 cm horizontally from the scar of the previous cesarean section, and the lateral end reached the upper lateral margin of the anterior superior iliac spine (Figures 1 [arrows] and 2). No pain or any other sign of inflammation was observed around the region. We discovered that the foreign body was the nonabsorbable suture material that had not been removed completely during the hospital stay. We thought that the remnant suture material had migrated laterally approximately 15 cm in dermis layer during the previous 5 months without any symptoms. Under local anesthesia with lidocaine, the material was removed easily through a 2-mm incision (Additional file 1: Video 1). The nylon suture material was confirmed, without the knot portion (Figure 3). The patient was discharged without any complications.

Figure 1
figure 1

The 10-cm thread-like object in the left lower quadrant of the abdomen (arrows).

Figure 2
figure 2

The fine, blue foreign body showing through the skin.

Figure 3
figure 3

The foreign body removed through a 2-mm skin incision. The nylon suture material was confirmed, without the knot portion.

Additional file 1: Video 1: The migrated suture material identified and removed through a skin incision. A 10-cm-long, fine, blue material is seen transversely in the left lower quadrant of the abdomen; the medial end is located approximately 5 cm horizontally from the scar of the previous cesarean section, and the lateral end has reached the upper lateral margin of the anterior superior iliac spine. No sign of inflammation is observed around the region. Under local anesthesia with lidocaine, the material is removed easily through a 2-mm incision. (WMV 11 MB)

Conclusions

Small remnants of nonabsorbable suture materials in the dermis or hypodermis (subcutaneous tissue) are known to migrate toward the superficial layer or occasionally to other sites within the human tissue. The phenomenon can be associated with complications, as reported in plastic surgeries such as blepharoptosis repair [3]. The mechanism of the migration was often thought to be related to foreign body immune reaction or to the force generated in wound contracture. However, no clear explanation has been proposed. To our knowledge, migration of relatively long suture materials, as in the present case, has not been reported yet. We retrieved related literature via PubMed by using keywords “migration”, “movement”, and “suture material”. In our case, the 10-cm length of the nylon suture migrated transversely to a relatively long distance (approximately 15 cm) within the dermis layer, without remarkable tangling of the entire length of the suture. Previously described mechanisms do not explain such uniform steady tension. Moreover, among suture materials, the nylon is known to have the least tissue reaction [4]. Some cases of migration of subcutaneous catheters, which are larger than suture materials, have been reported [5], but the mechanism of these migrations might be a shift in the subcutaneous fat pad due to position change, which is not applicable to the transverse migration of suture material.

Subcuticular skin sutures usually penetrate the dermis or superficial subcutaneous tissue. The subcutaneous tissue layer supports the mobility of dermal and epidermal skin layers [6]. The horizontal migration of the nonabsorbable suture in the present case might have occurred between the dermis and superficial subcutaneous tissue layers through the horizontal flow or movement of those layers, from the midline to the lateral side, during the recovery process or via mechanisms that have not been revealed yet.

More cases and studies are needed to explain the mechanism of the transverse migration of long suture materials. The results of these studies may provide evidence to better understand the movement of human tissues during wound recovery. Finally, practitioners need to be mindful that remnant suture materials can migrate to distant sites in rare cases. Careful exploration around the surgical wound might be helpful in these situations.

Ethics

We obtained approval of this study from the institutional review board of the Korea University Anam Hospital Clinical Trial Center (reference No. 2014-05-0009).

Consent

Written informed consent was obtained from the patient for the publication of this case report and any accompanying images. A copy of the written consent form is available for review by the editor of this journal.

References

  1. Tuuli MG, Rampersad RM, Carbone JF, Stamilio D, Macones GA, Odibo AO: Staples compared with subcuticular suture for skin closure after cesarean delivery: a systematic review and meta-analysis. Obstet Gynecol. 2011, 117 (3): 682-690. 10.1097/AOG.0b013e31820ad61e.

    Article  PubMed  Google Scholar 

  2. Genders RE, Hamminga EA, Kukutsch NA: Securing the subcuticular running suture. Dermatol Surg. 2012, 38 (10): 1722-1724. 10.1111/j.1524-4725.2012.02488.x.

    Article  CAS  PubMed  Google Scholar 

  3. Foster JA, John KB, Castro E, Meisler DM: Blepharoptosis surgery complicated by late suture migration. Am J Ophthalmol. 2000, 130 (1): 116-117. 10.1016/S0002-9394(00)00467-0.

    Article  CAS  PubMed  Google Scholar 

  4. Postlethwait RW, Willigan DA, Ulin AW: Human tissue reaction to sutures. Ann Surg. 1975, 181 (2): 144-150. 10.1097/00000658-197502000-00003.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  5. Nagasaka T, Inao S, Ikeda H, Tsugeno M, Okamoto T: Subcutaneous migration of distal ventriculoperitoneal shunt catheter caused by abdominal fat pad shift: three case reports. Neurol Med Chir. 2010, 50 (1): 80-82. 10.2176/nmc.50.80.

    Article  Google Scholar 

  6. Junqueira LCUA, Carneiro J, Contopoulos AN: Basic histology. A concise medical library for practitioner and student. 1975, Los Altos: Calif.: Lange Medical Publications, v

    Google Scholar 

Pre-publication history

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Soon Cheol Hong.

Additional information

Competing interests

The authors declare that they have no competing interests.

Authors’ contributions

All of the authors participated in the design of the study, acquisition, and interpretation of data, and drafting of the manuscript. All of the authors read and approved the final manuscript.

Authors’ original submitted files for images

Below are the links to the authors’ original submitted files for images.

Authors’ original file for figure 1

Authors’ original file for figure 2

Authors’ original file for figure 3

Rights and permissions

Open Access  This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made.

The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder.

To view a copy of this licence, visit https://creativecommons.org/licenses/by/4.0/.

The Creative Commons Public Domain Dedication waiver (https://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Ryu, KJ., Ahn, K.H. & Hong, S.C. Spontaneous complete migration of suture material after subcuticular continuous suture in cesarean section: a case report. BMC Surg 14, 103 (2014). https://doi.org/10.1186/1471-2482-14-103

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/1471-2482-14-103

Keywords