Correction to: Near-infrared auto-fluorescence spectroscopy combining with Fisher’s linear discriminant analysis improves intraoperative real-time identification of normal parathyroid in thyroidectomy

The Original Article was published on 06 January 2020

Correction to: BMC Surgery (2020) 20:4 https://doi.org/10.1186/s12893-019-0670-x

Following publication of the original article [1], we were notified of a few errors in partial data calculating and a spelling mistake in the footnote of Fig. 1d. These corrections do not change the main results and do not affect the conclusion in this article.

  • In the study [1], a total of 20 specimens were tested by near-infrared (NIR) auto-fluorescence system and the results were compared with the histology results. Among the 20 specimens, 19 parathyroid specimens were accurately detected and identified by NIR system. One suspicious parathyroid did not exhibit typical spectra, and was proved to be fat tissue by histology. So, all the 19 parathyroid glands were identified and the fat tissue (one specimen) was not regarded as parathyroid gland by the near infrared system. So, the sensitivity, the accuracy and the positive predictive value of the near infrared system should be 100% (19/19), 100% (20/20) and 100% (19/19), respectively. Our results indicate that the NIR auto-fluorescence spectroscopy can identify normal parathyroid gland with high accuracy and sensitivity. The correction does not change the main results and does not affect the conclusion in the article. On the contrary, the data indicate a better efficacy of NIR auto-fluorescence spectroscopy in identification of normal parathyroid gland.

  • In the footnote of Fig. 1d, thyroid was miswrote as parathyroid. The corrected footnote of Fig. 1d should be “The recovery courses of parathyroid function of four thyroid carcinoma patients undergoing total thyroidectomy with central neck dissection”.

Reference

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Xiaobao Yao.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Liu, J., Wang, X., Wang, R. et al. Correction to: Near-infrared auto-fluorescence spectroscopy combining with Fisher’s linear discriminant analysis improves intraoperative real-time identification of normal parathyroid in thyroidectomy. BMC Surg 21, 85 (2021). https://doi.org/10.1186/s12893-021-01071-z

Download citation

  • Published:

  • DOI: https://doi.org/10.1186/s12893-021-01071-z