Skip to main content

Table 2 Comparison of preoperative and final follow-up functional outcomes between the cemented polyethylene (PE) and convertible metal-backed (MB) groups

From: Can convertible metal-backed glenoid components replace cemented polyethylene glenoid components in anatomical total shoulder arthroplasty?

 

Cemented PE group

(n = 32)

Convertible MB group

(n = 18)

p-value

Follow-up, months

49.3 ± 21.8

32.6 ± 10.8

0.002*

Pain, VAS

   

Preoperative

7.0 ± 1.9

6.9 ± 1.3

0.805

Final follow-up

1.5 ± 2.2

0.5 ± 1.1

0.171

p-value

< 0.001*

< 0.001*

 

Forward flexion, °

   

Preoperative

110.9 ± 32.7

121.2 ± 33.7

0.199

Final follow-up

153.3 ± 15.9

158.1 ± 18.9

0.058

p-value

< 0.001*

< 0.001*

 

External rotation, °

   

Preoperative

29.6 ± 14.1

31.5 ± 11.7

0.385

Final follow-up

64.6 ± 16.9

67.6 ± 11.5

0.307

p-value

< 0.001*

< 0.001*

 

Internal rotation at back, VL

   

Preoperative

14.1 ± 2.9

13.3 ± 3.1

0.344

Final follow-up

9.6 ± 2.4

9.2 ± 2.0

0.862

p-value

< 0.001*

< 0.001*

 

ASES score

   

Preoperative

37.7 ± 18.6

42.5 ± 8.7

0.078

Final follow-up

87.2 ± 15.0

91.8 ± 12.3

0.246

p-value

< 0.001*

< 0.001*

 

SST

   

Preoperative

2.8 ± 2.3

3.1 ± 1.6

0.334

Final follow-up

8.6 ± 3.9

9.6 ± 2.6

0.546

p-value

< 0.001*

< 0.001*

 

DASH score

   

Preoperative

55.7 ± 22.9

46.2 ± 19.1

0.213

Final follow-up

10.8 ± 15.1

8.7 ± 8.9

0.999

p-value

< 0.001*

< 0.001*

 
  1. Data are presented as mean ± standard deviation
  2. * Statistically significant, ° Degrees
  3. VAS: visual analog scale, VL: vertebral level, ASES: American Shoulder and Elbow Surgeons Score, SST: simple shoulder test, DASH: Disabilities of the Arm, Shoulder, and Hand