Skip to main content

Table 2 Results comparison between the two groups

From: Comparative retrospective study of triangular osteosynthesis with and without robotic assistance for unilateral unstable sacral fractures combined with lumbosacral junction injuries

Characteristics

Robot group

Conventional group

t/X2

P value

Operation time of the posterior pelvic ring (min), M±SD

94.6±21.8

112.7±18.6

t=-2.347

0.027

The amount of surgical bleeding (mm)

98.2±36.1

286.8±92.7

t=-6.408

<0.001

Intraoperative fluoroscopy times, M±SD

24.1±6.3

34.1±8.4

t=-3.386

0.002

Maximum residual displacement

  

X2=1.056

0.543

 Excellent (0-5 mm)

9(81.8%)

16(82.4%)

  

 Good (6-10 mm)

2(18.2%)

1(17.6%)

  

Gras criterion on evaluation of sacroiliac screw position, n(%)

  

X2=1.638

0.355

 Grade I

10(90.9%)

12(70.6%)

  

 Grade II and III

1(9.1%)

5(29.4%)

  

Hospital stay(day)

14.2±5.4

21.0±8.4

t=-2.133

0.044

Healing time of sacral fractures (month)

3.7±1.5

4.9±1.2

t=-2.173

0.041

Majeed score

90.7±5.6

85.5±5.6

t=2.199

0.039