From: A novel method of lateral closing wedge osteotomy for cubitus varus deformity in children
 | Published (year) | Authors | Cases | Osteotomy method | Fixation materials | Oppenheim’s criteria |
---|---|---|---|---|---|---|
1 | 2019 | Yuan-Wei et al. [29] | 14 | Three-dimensional printing assisted osteotomy guide plate | K-wires | 13 Excellent, 1 good |
2 | 2019 | Hai et al. [30] | 13 | Computer simulation with lateral wedge osteotomy | K-wires | 10 Excellent, 2 good, 1 fair |
3 | 2019 | Karen et al. [31] | 1 | 3D-printed model with lateral wedge osteotomy | K-wires | 1 Excellent |
4 | 2018 | Hagay et al. [32] | 7 | Lateral closing wedge (French) osteotomy | Screws and wired | 6 Excellent, 1 good |
5 | 2017 | Pietro et al. [33] | 15 | Lateral wedge osteotomy | K-wires and locking angular plate | N/A |
6 | 2017 | PARTAP et al. [34] | 25 | Closed dome osteotomy | K-wires and mini external fixator | N/A |
7 | 2016 | Su et al. [14] | 25 | Lateral closing isosceles triangular osteotomy | K-wires | 23 Excellent, 2 good |
8 | 2016 | Travis et al. [24] | 16 | Dual-Planar Osteotomy | K-wires | 14 Excellent, 2 good |
9 | 2016 | Pankaj et al. [35] | 20 | Reverse V osteotomy | Cross K-wires and wiring or Y-shaped plate | 90% Excellent and 10% good |
10 | 2016 | David et al. [9] | 90 | Lateral closing wedge (French) osteotomy | Screws and wired | 84 Good or excellent, 6 poor |
11 | 2016 | Ayman et al. [36] | 20 | Dome osteotomy | Plate or K-wires | Fifteen excellent, five good |
12 | 2016 | Takehiko et al. [37] | 19 | Modified step-cut osteotomy | K- wires | 11 Excellent, 8 good |
13 | 2014 | Mehmet etc.[38] | 14 | Lateral closing wedge osteotomy | Methyl Methacrylate External Fixator | N/A |
14 | 2014 | Yashwant et al. [22] | 10 | Modified French osteotomy | Screws and wired | N/A |
15 | 2013 | Perajit et al. [39] | 18 | Double dome osteotomy | K-wires | 18 Excellent |
16 | 2013 | Hamdy et al. [40] | 6 | Closed wedge counter shift osteotomy | K-wires | 6 Excellent |
17 | 2013 | Yukari et al. [11] | 30 | Computer simulation-based, three-dimensional corrective osteotomy | K-wires | 27 Excellent, 3 good |
18 | 2011 | Tsuyoshi et al. [13] | N/A | Three-dimensional corrective osteotomy | K-wires | N/A |
19 | 2007 | Piskin et al. [23] | 23 | Distraction osteogenesis | Ilizarov frame fixation | 18 Excellent, 5 good |
20 | 2006 | Yun et al. [41] | 22 | Reverse V osteotomy | K-wires and wired | 20 Excellent and 2 good |