Table 2 Pressure tests of the descending aortas of pigs by staple-cartridge type

From: Safe transection of aberrant arteries associated with pulmonary sequestrations

Group

Diameter (mm)

Thickness (mm)

Staplar1

White

Blue

Green

Pressure (mmHg)

B shape2

Pressure (mmHg)

B shape2

Pressure (mmHg)

B shape2

S

ā‘ 

13.1

1.10

405

good

418

good

322

good

380

rupture

leakage

386

ā€•

ā€•

ā‘”

15.1

0.91

357

good

300

good

350

good

rupture

rupture

360

ā€•

ā€•

leakage

ā‘¢

16.2

0.99

320

poor

290

good

220

good

170

190

168

leakage

rupture

ā€•

average

14.8ā€‰Ā±ā€‰1.6

1.00ā€‰Ā±ā€‰0.10

336.3ā€‰Ā±ā€‰86.5

ā€•

299.5ā€‰Ā±ā€‰93.3

ā€•

284.0ā€‰Ā±ā€‰85.3

ā€•

L

ā‘£

23.6

1.70

314

poor

171

good

323

good

leakage

169

303

ā€•

rupture

272

ā‘¤

21.8

1.23

230

poor

186

good

309

good

125

rupture

300

leakage

ā€•

298

ā‘„

20.3

1.70

220

poor

269

poor

223

good

149

220

276

leakage

leakage

263

average

21.9ā€‰Ā±ā€‰1.6

1.54ā€‰Ā±ā€‰0.27

207.6ā€‰Ā±ā€‰74.6

ā€•

203.0ā€‰Ā±ā€‰42.2

ā€•

285.2ā€‰Ā±ā€‰30.2

ā€•